SRM6-12 Gas Insulated Metal Enclosed Switchgear
SRM6-12 gas-insulated metal-enclosed switchgear is a three-phase AC 50Hz, fully insulated and fully sealed metal-enclosed switchgear using SF6 gas.
Key words:
Key words:
Jiangxi Ganzhong Transformer Co., Ltd
Classification:
Message consultation
Previous Page
Product Details
Product Overview
The SRM6-12 gas-insulated metal-enclosed switchgear is a three-phase AC 50Hz, fully insulated and fully sealed metal-enclosed switchgear using SF6 gas.
It adopts a modular design, using vacuum circuit breakers, load switches, load switch-fuse combination devices, isolating switches, and other main switches as functional units, placed in a sealed gas chamber to form various gas-filled compartment units. The busbar can be expanded in the left and right directions through busbar connectors, and the incoming and outgoing lines use plug-in cables. It is not affected by the environment, has high safety, is maintenance-free, and has strong reliability.
Widely used in industrial and civil ring network distribution systems and power supply terminals, especially suitable for small secondary substations, industrial and mining enterprises' switchgear, urban residential communities, airports, railways, and other places.
Model Meaning
Usage Conditions
◌ Ambient air temperature: -40℃ ~ +40℃, daily temperature difference: not exceeding 35℃;
◌ Altitude not exceeding 4000m (if the operating altitude exceeds 1000m, please specify!);
◌ Ambient air is not polluted by corrosive gases or flammable and explosive gases, and the installation site is free from severe shocks; the pollution level does not exceed the III level specified in GB/T5582;
◌ Seismic intensity: level 8;
◌ The amplitude of electromagnetic interference induced in the secondary system does not exceed 1.6kV;
◌ Special usage conditions: If different from the above usage conditions, the user needs to negotiate with the manufacturer to reach a consensus.
Technical Parameters
Item | Unit | Load Switch Unit | Combination Device Unit | Circuit Breaker Unit | |
Rated Voltage | kV | 12/24 | |||
Rated Frequency | Hz | 50/60 | |||
Main Bus Rated Current | A | 630, 1250 | |||
Rated Current | 630 | 125 | 630, 1250 | ||
Rated Short-Circuit Breaking Current | kA/ times | 31.5 | 20, 25/30 | ||
Rated Short-Circuit Closing Current (Peak Value) | kA | 50 | 80 | 50, 63 | |
Rated Short-Time Withstand Current | Main Circuit 4s/ Ground Circuit 4s | kA | 20 | 20, 25 | |
Ground Connection Circuit 4s | 17.4 | 17.4, 21.7 |